14.3.1
Installation using the alignment
bracket method
Original instructions
1
3
2
1
Set the alignment brackets to position 2.
3
Secure the readhead using 2 × M6 screws; tighten screws to a torque of
8 Nm.
2
Slide the readhead to align the readhead mounting holes to the machine
slideway mounting holes.
4
4
8 Nm
Pull alignment bracket lever upwards into position 3 to open the alignment
bracket. Slide the alignment brackets away from the readhead and remove
from the extrusion.
NOTE: The alignment brackets must be removed after installation.
Machine slideway
mounting holes
17