Position Control Mode (Pulse Position Command Input) - HNC Electric SV-E3 Series Instruction Manual

Table of Contents

Advertisement

Press
button
Press
button once
Press
button to set the related parameters. We can go to the next step after all the parameters are set.
Press
three times
Press
button once
-
Note 1: The control power for models of 750W or less is supplied from external 24VDC.For 1kW or more, is supplied from
internal. Therefore, the control power for models of 1kW or more can be ON/OFF by switching on/off the AC power supply of
main circuit.

8.2 Position control mode (Pulse position command input)

8.2.1 Wiring for user I/O connector (CN1) (Differential input)
Name
Symbol
User I/O
CN1
●24V power
supply input
●Parallel I/O
●Pulse command
input
●ABZ output
Return to the display to change the parameter No.
(Display parameter 2.0)
Press UP button to change the parameter No.
Display parameter 3.0.
Display the setting value of parameter 3.0.
Switch to the mode of setting panel.
Switch to parameter saving mode.
Save the parameter to the EEPROM in drive.
(When saving, 『P』 in 『SAVE_P』 will flicker.)
To the end.
Please cut off the power supply to the drive and restart. After restart the power, the setting
will be effective.
Terminal
Signal name
No.
1
24V
2
G24V
3
COM+/-
4
SVON
5
RESET
6
HOLD
7
PCLR
8
-
9
CCWL
10
CWL
11
TLSEL1
12
COM-
13
MBRK
14
SERVO
15
POSIN
92
Contents
Drive control power supply 24V input
Drive control power supply GND
I/O power supply 24V input
Servo ON input
Alarm reset input
Command input restriction
Deviation counter clear input
Reserved
CCW drive input restriction
CW drive input restriction
Torque limit input
I/O power supply GND
Brake release output
Servo status output
Position completion output