Alarm Display Mode - HNC Electric SV-E3 Series Instruction Manual

Table of Contents

Advertisement

in07
Reserved
『-』fixed
Operating procedures of regenerative status are as follows.
Press the "UP" or "DOWN" button, the number will be displayed alternatively. When input signal displays, press "SHIFT"
button and it will shift to output signal 「ot00」 . When output signal displays, press "SHIFT" button and it will shift to input signal
「in00」
Figure 5.4.5
Follow above operating procedures to confirm whether a regenerative resistor is needed or not. When the display changes
from 「in00_-」 to 「in00_A」 , the regenerative discharge is opened and the regenerative resistor is needed. For details, refer
to [Regenerative resistor]. Starting from low speed (20% of the highest speed), operating the motor to the expected movement
slowly and
observing if the display value changes from「in00_-」to「in00_A」 If 「in00_A」 displays, a regenerative resistor
is needed. Operation panel displays as follow:
Need a regenerative resistor
Do not need any regenerative resistor

5.5 Alarm display mode

The following shows the operating procedures of alarm display.
Press the "MODE" button three times from the beginning,「dP_Err」 indicates the alarm display mode. Press the "SET" button
to display the drive alarm status and 「Err.--」indicates no alarm. If an alarm has occurred, the corresponding alarm number is
output on the right side of 「Err.」. For the details of alarm number, refer to the following [Alarm items]. If several alarms have
occurred, press "UP" or "DOWN" button to display the alarm number.
When an alarm has occurs, 「Err.**」will be displayed on the operation panel except these four modes. (** indicates the alarm
number) ①Parameter setting mode, ②Auto tuning mode , ③In Parameter saving mode, ④Auxiliary functions, when press
48