Speed Control Mode (Internal Speed Command) - HNC Electric SV-E3 Series Instruction Manual

Table of Contents

Advertisement

actual operation. Then confirm the operation until it comes to the specified speed.
Note1: The control power supply for the models of 750W or less are supplied by external 24V DC. 1kW or more are supplied
from internal. So the control power supply of models of 1kW or more can be ON or OFF by switching on or cutting off the main
circuit AC power.

8.4 Speed control mode (Internal speed command)

8.4.1 Wiring for user I/O connector(CN1) (Internal speed command)
Name
Symbol
User I/O
CN1
●24V power
supply input
●Parallel I/O
●Pulse command
input
●Analog input
●ABZ output
Pin No.
Signal name
1
24V
2
G24V
3
COM+
4
SVON
5
RESET
6
VCRUN1
7
VCRUN2
8
VCSEL1
9
VCSEL2
10
VCSEL3
11
TLSEL1
12
COM-
13
MBRK
14
SERVO
15
-
16
-
17
T-LIMIT
18
OCZ
19
SRDY+
20
SRDY-
21
ALM+
22
ALM-
23
NC1
24
-
25
-
26
-
108
Contents
Drive control power supply 24V input
Drive control power supply GND
I/O power supply 24V input
Servo ON input
Alarm reset input
Input internal speed command-start 1(CCW ON)
Input internal speed command-start 1(CW ON)
Input internal speed command-Speed command
selection 1
Input internal speed command-Speed command
selection 2
Input internal speed command-Speed command
selection 3
Torque limit input
I/O power supply GND
Brake release output
Servo status output
Reserved
Reserved
Torque limit output
Encoder Z-phase output (open collector)
Servo ready output +
Servo ready output -
Servo alarm output+
Servo alarm output-
Reserved (Disconnected)
Reserved
Reserved
Reserved

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents