Speed Control Mode (Analog Speed Command Input) - HNC Electric SV-E3 Series Instruction Manual

Table of Contents

Advertisement

a low speed(100r/min). Make sure the rotation direction of the motor is same to the setting direction.
6
Improve the position command pulse frequency gradually after confirming the safe implementation of
actual operation. Then confirm the operation until it comes to the specified speed.
Note1: The control power supply for the models of 750W or less are supplied by external 24V DC. 1kW or more are supplied
from internal. So the control power supply of models of 1kW or more can be ON or OFF by switching on or cutting off the main
circuit AC power.

8.3 Speed control mode (Analog speed command input)

8.3.1 Wiring for user I/O connector(CN1) (Analog speed command input)
Name
Symbol
User I/O
CN1
●24V power
supply input
●Parallel I/O
●Pulse command
input
●ABZ output
Pin No.
Signal name
1
24V
2
G24V
3
COM+
4
SVON
5
RESET
6
HOLD
7
-
8
-
9
CCWL
10
CWL
11
TLSEL1
12
COM-
13
MBRK
14
SERVO
15
-
16
-
17
T-LIMIT
18
OCZ
19
SRDY+
20
SRDY-
21
ALM+
22
ALM-
23
NC1
24
-
25
-
26
-
27
-
103
Contents
Drive control power supply 24V input
Drive control power supply GND
I/O power supply 24V input
Servo ON input
Alarm reset input
Command input restriction(Zero speed clamp)
Reserved
Reserved
CCW drive input restriction
CW drive input restriction
Torque limit input
I/O power supply GND
Brake release output
Servo status output
Reserved
Reserved
Torque limit output
Encoder Z-phase output (open collector)
Servo ready output +
Servo ready output -
Servo alarm output+
Servo alarm output-
Reserved (Disconnected)
Reserved
Reserved
Reserved
Reserved

Hide quick links: