Parameterisation
Fail Safe State and Idle State Objects for Digital Output Modules
Object classes:
Fail safe state: 112
Idle state: 114
Instances: 1 ... 48
Attribute no.
Access
1
Get/Set
2
Get/Set
...
...
64
Get/Set
100
Get
101
Get
Tab. 41 Fail Safe State and Idle State Objects for Digital Output Modules
Fail Safe State and Idle State Objects for Analogue Output Modules
Object classes:
Fail safe state: 120
Idle state: 122
Instances: 1 ... 48
Attribute no.
Access
1
Get/Set
2
Get/Set
...
...
32
Get/Set
Tab. 42 Fail Safe State and Idle State Objects for Analogue Output Modules
Fail Safe State and Idle State Objects of Technology Modules
Object classes:
Fail safe state: 128
Idle state: 130
44
d
d
Description
Channel 0
0 = Hold last state
1 = Fail safe/Idle state
Channel 1
0 = Hold last state
1 = Fail safe/Idle state
...
Channel 63
0 = Hold last state
1 = Fail safe/Idle state
Number of channels
All channels: values for Fail safe state and Idle
state
d
d
Description
Channel 0
Value for Fail safe state/Idle state
Channel 1
Value for Fail safe state/Idle state
...
Channel 31
Value for Fail safe state/Idle state
d
d
Type
BOOL
BOOL
...
BOOL
BYTE
ARRAY
Type
WORD
WORD
...
WORD
Festo — CPX-E-EP — 2020-01a