Parameterisation
Attribute no.
Access
1
Get/Set
...
...
4
Get/Set
Tab. 23 IO-Link Port Configuration Object
ISDU Access Object
Request
Service code Instance
Read
0x32
Write
0x33
1) values: 1 = port 1; 2 = port 2; etc.
Tab. 24 ISDU Access Object
Read response data
Data [0]
30
Description
Port 1 configuration
–
Master cycle time in 100 s (default 0)
–
Inspection level (default 0)
–
0 = No check
–
1 = Type compatible (check vendor and
device ID)
–
2 = Identical (check serial, vendor and
device ID)
–
Expected vendor ID (default 0)
–
Expected device ID (default 0)
–
Expected serial
...
Port 4 configuration
–
Master cycle time in 100 s (default 0)
–
Inspection level (default 0)
–
0 = No check
–
1 = Type compatible (check vendor and
device ID)
–
2 = Identical (check serial, vendor and
device ID)
–
Expected vendor ID (default 0)
–
Expected device ID (default 0)
–
Expected serial
Attributes
Channel
Module
1)
1)
Channel
Module
Data [1
n]
...
Data [0 ... 1] Data [2]
Index
Subindex
Index
Subindex
Write response data
Data [0]
Festo — CPX-E-EP — 2020-01a
Type
STRUCT of
UINT
USINT
UINT
UDINT
STRING
...
STRUCT of
UINT
USINT
UINT
UDINT
STRING
Data [3 ... n]
–
Data to write