Parameterisation
3.2.2
Behaviour after SCS
The "Behaviour after SCS" parameter defines whether the voltage remains deactivated or reactivates
automatically after a short circuit or overload at the IO-Link® interfaces (ports).
The voltage can be switched on again with the "leave switched off" setting by deactivating and then
reactivating the "PS supply" (è Tab. 19) parameter. Otherwise the activation and deactivation of the
automation system CPX-E is required to restore the voltage.
Parameter – Behaviour after SCS
Setting
Leave voltage deactivated Leave deactivated
Reactivate voltage auto-
matically again
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 17
3.2.3
Behaviour after SCO
The "Behaviour after SCO" parameter defines whether the voltage remains deactivated or reactivates
automatically after a short circuit or overload at the IO-Link® interfaces (ports).
The voltage can be switched on again with the "leave switched off" setting by deactivating and then
reactivating the "PS supply" (è Tab. 19 ) parameter. Otherwise the activation and deactivation of the
automation system CPX-E is required to restore the voltage.
Parameter – Behaviour after SCO
Setting
Leave load voltage deac-
tivated
Reactivate load voltage
automatically
1) Function number (è Description of automation system CPX-E); m = module number (counted from left to right, starting from 0)
Tab. 18
18
Selection via software
reactivate (default)
Selection via software
Leave deactivated
reactivate (default)
Selection via parameter
F no.
Bit
1)
4828 +
7
6
5
64m
+ 1
+ 1
Selection via parameter
F no.
Bit
1)
4828 +
7
6
5
64m
+ 1
+ 1
Festo — CPX-E-4IOL-... — 2020-01a
4
3
2
1
0
0
1
4
3
2
1
0
0
1