excluding "S9".<R>
Makes the line add up to "FF"
@LIST 1 = 13-14
@LIST 2 = Carriage Return & Line Feed
@LISTING =
Tektronix<$IFile
Formats;TekHex> Format
<$ITEKHEX File Format>A Tektronix format file
can be examined using
a text editor and printed.<R>
Each record is a single line of ASCII characters,
expressing bytes
as hexadecimal pairs, terminated with Carriage
return and Linefeed
(0D,0A). <R>
The transmission is terminated by ASCII End-of-
File (1A).
Tek Standard Data Record.
@LIST 1 = Position
@LIST 2 = Character
@LIST 1 = 1
@LIST 2 = "/" Slash character
@LIST 1 = 2-5
@LIST 2 = Four HEX characters show two byte
Load Address, most significant
byte first.
@LIST 1 = 6-7
@LIST 2 = Two HEX characters show Byte Count
(how many Data Bytes
not including checksums, % or address)
@LIST 1 = 8,9
@LIST 2 = Two HEX characters show checksum
of HEX characters in Load
Address and Byte Count.