1.
Select Debug>Check Parameter and Data Values from the menu bar.
A message box appears to show the check result. If there is an error in the settings for the
positioning data tables, an error message will appear and the cursor will move to the
corresponding error position.
4.2.7 Writing Parameters to Unit (1)
● Information on parameters that have been set is transferred to the unit along with information
on programs, comments and system registers.
● The following procedure is explained on the condition that the Configurator PMX has already
started.
1.
Select File>Save changes and exit from the menu bar of the Configurator PMX.
2.
When "Do you save the setting?" appears, press [Yes (Y)].
3.
Select Online>Download To PLC (Entire project) from the FPWIN GR7 menu bar.
Positioning data will also be downloaded to the control unit along with information on
programs, comments and system registers.
4.2.8 Writing Parameters to Unit (2)
● Information on parameters that have been set can also be downloaded to the unit in the
Configurator PMX.
● The following procedure is explained on the condition that the Configurator PMX has already
started.
1.
Select File>Download positioning data from the menu bar of the Configurator PMX.
A message box for confirming the saving appears.