Download Print this page

Panasonic FP-XH Series User Manual page 186

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

11.3 Positioning Memory
Address
Name
Positioning repeat
count
0003
(CH2)
Positioning repeat
count
0004
(CH3)
Positioning repeat
count
0005
(CH4)
Positioning repeat
count
0006
(CH5)
0007
Error code
0008
Reserved for system
to 0029
11.3.3 Axis Information Area (Memory Area No. 1)
●: Available, -: Not available
Offset
Name
address
Active or execution
0000
done table
Repeat count current
0001
value
0002
Elapsed value (Current
value coordinate)
-0003
0004
Reserved for system
-0009
11-14
Default
Description
K0
Set value
255 or more
K0
-
-
Stores a generated positioning error code in Hex
format (hexadecimal) when using the pulse output
function (table setting mode).
H0
The higher 8 bits indicate channel number.
The lower 8 bits indicate error code.
-
-
Default
Description
Stores the monitor values of the positioning
table numbers during the execution or on the
K0
completion of each channel.
Stored value: 0-20
Stores the repeat count during the operation of
each channel. The execution start time is
counted as "1". When the repeat count exceeds
the upper limit, it returns to "0". When the repeat
K0
operation is not enabled, "0" is stored at the
positioning control start time.
Stored value: 0-65535
Stores the elapsed values (current value
coordinate) of each channel.
Range: -1,073,741,824 to 1,073,741,823
K0
For the interpolation control, the setting range is
as follows.
-8,388,608 to +8,388,607
-
-
Operation
Repeat an operation infinitely.
R
W
-
-
-
R
W
-
-
-
-
WUME-FPXHPOSG-01

Advertisement

loading