Download Print this page

Panasonic FP-XH Series User Manual page 135

Programmable controller
Hide thumbs Also See for FP-XH Series:

Advertisement

3.
Change the settings for the channels used for the PWM output.
4.
Press the [OK] button.
The screen returns to the ladder edit screen. The settings will be downloaded to the PLC
together with programs and comments.
System register relating to PWM output
Classification
Transistor output type
Control Unit output
settings
(PLS / PWM)
Relay output type
Pulse I/O setting
(PLS / PWM)
(Note 1)
Displayed items and ranges vary depending on models of the Control Unit.
(Note 2)
Select "Normal output" for the output that is not used for the pulse output function or PWM output
function.
WUME-FPXHPOSG-01
No. and setting item
402
Pulse / PWM output
setting
(Y0 to YB)
Pulse output setting
(Y100 and Y101)
Pulse output setting
(Y200 and Y201)
9.1 PWM output function
Settings
Set the PWM output (Y0) and normal output
CH0
(Y1).
Set the PWM output (Y2) and normal output
CH1
(Y3).
Set the PWM output (Y4) and normal output
CH2
(Y5).
Set the PWM output (Y6) and normal output
CH3
(Y7).
CH4
The PWM output cannot be allocated.
CH5
Set the PWM output (Y100) and normal output
CH0
(Y101).
Set the PWM output (Y200) and normal output
CH1
(Y201).
9-3