5.4 Positioning Control
Operation diagram
f [Hz]
20,000Hz
15,000Hz
10,000Hz
1,000Hz
Instruction
start condition
Busy signal
Operation
done signal
J-point speed
change contact
J-point positioning
start contact
Operations of each contact
● The BUSY flags (X28 and X29) will turn ON when the operation starts and turn OFF when
the operation is completed.
● The operation done flags (X30 and X31), which indicate the completion of operation, will turn
ON when the current operation is completed, and they will be held until the next positioning
control, JOG operation or home return operation starts.
● The target speed will be changed when the J-point speed change contacts (Y60 and Y61)
turn ON. The change will be enabled at the edge where the contact turns ON.
● Positioning control will start when J-point positioning start contacts (X0 and X1) turn ON.
Characteristics of acceleration / deceleration zone when changing speeds
● The speed of speed change zone changes for each scan when changing the speed in the J-
point control. The speed variation is obtained by the following formula.
(J-point table target speed - Startup speed) / (J-point table acceleration time or J-point table
deceleration time)
Settings
Item
Axis setting area
Table area
5-24
J-point speed
Ta ble 1
100ms
Approx. 50 ms
Startup speed
J-point change speed
Table number
Control method
change
100000
150 ms
Setting example
1,000 Hz
10,000 Hz
Table 1
Increment mode
Ta ble 2
pulses
250ms
50ms
Table 2
Increment mode
WUME-FPXHPOSG-01
t [ms]