Oki Data CONFIDENTIAL
4.2.4 Right side cover
(1) Open the scanner and the top cover.
(2) Remove the cassette assembly.
(3) Remove the interface cover ① .
(4) Loosen the screw ② to remove the bracket ③ .
(5) Open the MPT assembly.
(6) Remove the three screws ④ .
(7) Unlatch two portions A and seven portions B to detach the right side cover ⑤ .
Note! Please pull out SD Memory card, when you exchange Cover-Side(R) ⑤ .
(MC562/MC562dw)
44952001TH Rev.2
Scanner
Top cover
Latches B
MPT Assy
Latches A
4.REPLACEMENT OF PARTS
Latches B
Latches B
4-6