Oki MC362w Maintenance Manual page 152

Hide thumbs Also See for MC362w:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Item1
Item2
Item3
Password
Scanner
Adjust Mech.
Maintenance
Adjust CIS
44952001TH Rev.2
Item4
Item5
Value
Adjust ADF
ADF Drive
10 ~ 1400
Motor
Current 4
ADF Keep
10 ~ 1400
Current
Adjust CIS
simple
R continuous
G continuous
B continuous
All continuous
Check CIS
300dpi
600dpi
1200dpi
--- Results displayed ---
CCD_SIG9_WID_H 0 x 000000
CCD_SIG2_WID_H 0 x 000000
Set CIS
0 ~ 4294967295
Exposure
time
Default
Default
Default
value
value
value
ODA
OEL
JP
800
800
800
Only for engineering test
[mA]
[mA]
[mA]
Connect a panel or PC and set the electric current value of the scanner motor.
200
200
200
[mA]
[mA]
[mA]
Only for engineering test
Sequentially light the designated RGB colors and check them during calibration
configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in the same manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→ On the panel, display "CIS light testing" and "Cancel."
Only for engineering test
Check CIS maintenance displays the exposure time at each resolution.
When resolution is set, scanner calibration is conducted at that resolution and the
following results are displayed:
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
Note: CIS exposure time varies with resolution.
Only for engineering test
Change LED exposure time settings, and then read the document using PC Scan.
Reading implemented for the LED exposure time in the settings, without conducting
calibration.
A warning is displayed when a value greater than the Lsync cycle has been set.
Settings are shown below.
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
5. MAINTENANCE MENUS
Notes
5-5