Solid State Logic C100 HDS Installation Manual page 98

Digital broadcast console
Hide thumbs Also See for C100 HDS:
Table of Contents

Advertisement

SNMP
B-Rio SnMp o
BjectS
The individual SNMP objects for B-RIO units that are exported from V1.1/5 software are as follows:
object
sslRioIndex
sslRioPresent
sslRioVersion
sslRioTemp1
sslRioTemp2
sslRio1v2
sslRio3v3r1
sslRio3v3r2
sslRio5v
sslRio5v5
sslRio15V
sslRioMinus15V
sslRioCardsInfo
SSLC110NowDormantInRedundantPair
SSLC110DiskStatusNotify
SSLC110RaidStatusNotify
B-Rio SnMp t
RApS
The standard 'trap' objects that are available for B-RIO units in V1.1/5 software are as followings:
object
sslRioOnline
sslRioOffline
sslRioChassisFan1Fail
sslRioChassisFan2Fail
sslRioPsu1Fail
sslRioPsu2Fail
sslRioPsu1FanFail
sslRioPsu2FanFail
f
i
URtHeR
nfoRMAtion on
A great deal of information regarding SNMP is of course available from the internet whilst a highly recommended book is
'Essential SNMP, 2nd edition', published by O'Reilly Media (ISBN10: 0-596-00840-6, ISBN13: 9780596008406).
Page 4-22
|
Section 4 – Appendices
type
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
read-only
System
SBC
SBC
from
B-RIO
B-RIO
B-RIO
B-RIO
B-RIO
B-RIO
B-RIO
B-RIO
SnMp
description
The index of the B-RIO unit – up to 8 units may be
connected and addressed
Indicates if a B-RIO unit is connected to the system
Carries the B-RIO firmware version string
Temperature reading in degrees Celcius from the primary
internal temperature sensor
Temperature reading in degrees Celcius from secondary
internal temperature sensor
Voltage reading from the +1.2V rail
Voltage reading from the +3V3 rail (primary sensor)
Voltage reading from the +3V3 rail (secondary sensor)
Voltage reading from the +5V rail
Voltage reading from the +5V5 rail
Voltage reading from the +15V rail
Voltage reading from the –15V rail
A string providing details of which I/O cards are currently
fitted to this B-RIO
Blackrock processor is now the dormant member of a
redundant pair
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager
description
A B-RIO unit has come online
A B-RIO unit has gone offline
B-RIO chassis fan 1 failure
B-RIO chassis fan 2 failure
B-RIO PSU 1 failure
B-RIO PSU 2 failure
B-RIO PSU 1 fan failure
B-RIO PSU 2 fan failure
C100 HDS Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C100 HDS and is the answer not in the manual?

Questions and answers

Table of Contents