c100 HdS SnMp t
The standard 'trap' objects that are available for the C100 HDS system in V1.1/5 software are shown in the following table.
object
SSLC110Restarting
SSLC110MemLow
SSLC110DspReboot
SSLC110DspRebootFail
SSLC110Psu1Fail
SSLC110Psu2Fail
sslC110PsuFanFail
SSLC110MainGfx1Fail
SSLC110MainGfx2Fail
SSLC110LostTileComms
SSLC110ResumedTileComms
SSLC110Synclost
SSLC110SyncReturned
SSLC110NowActiveInRedundantPair
SSLC110NowDormantInRedundantPair
SSLC110DiskStatusNotify
SSLC110RaidStatusNotify
C100 HDS Installation Manual
RApS
from
System
System
System
System
Processor
Processor
Processor
Console
Console
System
System
System
System
System
System
SBC
SBC
description
System restarting
Blackrock DSP card memory low
A DSP device on the Blackrock DSP card has rebooted
A DSP device on the Blackrock DSP card has failed to
reboot
Blackrock processor PSU 1 failure
Blackrock processor PSU 2 failure
Blackrock processor fan failure
Primary console TFT meter driver failure
Secondary console TFT meter driver failure
Lost Ethernet communication to the control surface
Recovered Ethernet communication with the control
surface
External (Video/AES) sync lost
External (Video/AES) sync recovered
Blackrock processor is now the active member of a
redundant pair
Blackrock processor is now the dormant member of a
redundant pair
SBC system disk SMART status trap. This will be sent upon
receiving a SMART error from the system hard disks
SBC RAID disk array status trap. This will be sent upon
receiving a change in status from the system RAID disk
array manager