Download Print this page

Victron energy Color Control GX Manual page 44

Hide thumbs Also See for Color Control GX:

Advertisement

Last update: 2020-08-19 12:10
Error #154 DNS Failure: Make sure that a valid DNS server is configured in the Ethernet or WiFi
menu. Typically this is assigned automatically by a DHCP server in a network.
Error #155 Routing error: VRM is unreachable. This error occurs if an ICMP error is received
indicating that no route exists to the VRM server. Make sure your DHCP server assigns a
working default route, or that the gateway is correctly configured for static configurations.
Error #159 Unknown error: this is a catch-all error for errors that cannot be directly categorised.
In such cases the Error message will provide information about the problem.
.
Check 'Last contact'. If this shows dashes, the GX device has not been able to contact the VRM Portal
since power up. If it shows a time, but still an error is shown, then the GX device has been able to
send data, but has since lost contact.
The 'Buffered items' indicates the number of logs that it has stored to send later. If this is larger than
0, it means that the CCGX can not connect to the VRM Portal. All data is sent using the First in First
out principle: the VRM Portal will only show the most up to date information after all old data has been
sent.
5.5 Analysing data offline, without VRM
In certain cases, for example for very remote sites where there is no internet available, it can be
useful to be able to analyse the data without first having to upload it to the VRM Portal.
1.
Install VictronConnect on a Windows or Apple laptop
https://www.victronenergy.com/live/
ccgx:start https://www.victronenergy.com/live/ccgx:start?rev=1597831811
Printed on 2020-11-10 02:37