combination with function Fluid Level (150).
A single function reporting multiple Fluid Levels is currently not supported.
For some tank senders it is also possible to configure the capacity and the fluid type on the GX Device
menus - for example the Maretron TLA100. This facility may be available with other senders made by
other manufacturers - it's well-worth trying.
Tested compatible NMEA2000 tank senders:
Maretron TLA100
Maretron TLM100
Navico Fluid Level Sensor Fuel-0 PK, partno. 000-11518-001. Note that you need a Navico
display to configure the Capacity, Fluid type, and other parameters of the sensor. See voltage
warning below
Oceanic Systems (UK) Ltd (OSUKL) - 3271 Volumetric Tank Sender. In case it doesn't work, it
needs a firmware update. Contact OSUKL for that. See voltage warning below
Oceanic Systems UK Ltd (OSUKL) - 3281 Water Level Sender. See voltage warning below
Most likely others work as well. If you know of one working well, please edit this page -or- get in touch
with us on
Community ->
To connect an NMEA2000 network to the VE.Can port on the CCGX, which both have different type
connectors, there are two solutions:
1.
The
VE.Can to NMEA2000
either power the NMEA2000 network with Victron equipment, or not. Take note of below
warning.
2.
The
3802 VE.Can Adapter by
single NMEA-2000 device such as a tank sender into a VE.Can network. It's also able to power a
lower voltage NMEA-2000 network directly from a 48V Victron system.
Warning and solution for 24V and 48V systems
Whilst all Victron components can work up to 70V input on their CAN-bus connections, Oceanic and
Navico senders cannot. They require a 12V powered NMEA2000 connection, as that is what they use
to power their sensor circuitry. See above 3802 VE.Can Adapter by OSUKL for a solution.
1.10 Connecting IMT Solar Irradiance, Temperature and Wind Speed Sensors
1.10.1 Compatibility
Ingenieurbüro Mencke & Tegtmeyer GmbH (IMT) offer a range of digital silicon irradiance sensor
models within the
Si-RS485 series
The optional/additional external
are also supported.
Optional/additional external sensors are either connected to the solar irradiance sensor with pre-
installed plugs or pre-wired to the solar irradiance sensor (external module and ambient temperature
only). When external sensors are connected via an appropriate solar irradiance sensor, all
https://www.victronenergy.com/live/
Modifications.
cable. Which by either inserting or leaving out the fuse allows to
OSUKL. Its advantage is that it lends itself well to connecting a
that are all compatible with a Victron GX device.
module temperature, ambient temperature
ccgx:start https://www.victronenergy.com/live/ccgx:start?rev=1597831811
and
wind speed
sensors
Printed on 2020-11-10 02:37

Advertisement

loading
Need help?

Need help?

Do you have a question about the Color Control GX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ccgx