Download Print this page

Advanced Menu - Victron energy Color Control GX Manual

Hide thumbs Also See for Color Control GX:

Advertisement

Last update: 2020-08-19 12:10
The alarm shows as a Notification in the GUI, and as an alarm on the VRM Portal, and is available on
ModbusTCP / MQTT.
Recommend to use for backup systems. But also for yachts or vehicles on shore power.
Note that this settings monitors that the system is connected to grid/shore. Generator monitoring is
already available as part of the Generator start/stop function and not part of this.
Do not use this feature in systems that use the Ignore AC Input settings in our inverter/chargers:
when the system ignores the AC input, ie runs in island mode, as intended, even though grid is
available, it will report a grid failure.

3.4 Advanced menu

Equalisation
Starts equalisation. See Multi or Quattro documentation for details.