The table below describes the colour and function of each wire in the installation.
IMT Si-RS485 Series Irradiance
Sensor
Brown
Orange
Red
Black
Black Thick
-
-
-
-
1.10.4 Installation Notes
1- The maximum DC power supply voltage permitted for the IMT Si-RS485 series solar irradiance
sensor range is 28.0 VDC - accordingly for 24 V and 48 V battery banks/systems an appropriate
Victron DC-DC converter
installation.
For 12 V battery banks/systems the IMT Si-RS485 series solar irradiance sensor range may be
powered directly from the battery bank and will continue to operate down to minimum voltage of 10.5
V (as measured at the sensor, account for voltage drop in the cable).
https://www.victronenergy.com/live/
Victron RS485 to USB
Interface
Orange
Yellow
-
-
-
Red
Black
Brown
Green
(24/12, 24/24, 48/12 or 48/24) or AC-DC adaptor must be utilised in the
ccgx:start https://www.victronenergy.com/live/ccgx:start?rev=1597831811
Description
RS485 Data +
RS485 Data -
Power Pos - 12 to 28 VDC
Power Neg/Gnd - 0 VDC
Cable Shield - PE
Power Pos - 5 VDC (not used)
Power Neg/Gnd - 0 VDC (not used)
Terminator 1 - 120R (not used)
Terminator 2 - 120R (not used)