7 Transfer of Parameter Settings
Reg.
Param.
Name
No.
No.
Superimposed
Harmonic Polarity
0x0568 N8-41
Estimation
Proportional Gain
Integral Time for
Superimposed
0x0569 N8-42
Harmonic Polarity
Estimation
Acceleration Time
0x053E N8-51
Pull-In Current*
Light Load Iq
0x05C3 N8-74
Level
Medium Load Iq
0x05C4 N8-75
Level (low)
Heavy Load Iq
0x05CE N8-77
Level
Medium Load Id
0x05F4 N8-78
Current
Drive Mode Unit
0x0500 O1-01
Monitor Selection
Digital Operator
0x0502 O1-03
Display Selection
0x0504 O1-05 LCD Contrast
Drive U1 Monitor
0x164A Q2-11
Select 1
Drive U1 Monitor
0x164B Q2-12
Select 2
Auto-Tuning Mode
0x0701 T1-01
Selection
0x0702 T1-02
Motor Rated Power
38
Description
Sets the P gain for PI control used to estimate
polarity.
There is usually no need to change.
You set the response of the speed estimation for
high frequency injection. N8-57 (high frequency
superimposed selection) is valid at the time of
the 1.
Unit [Hz]
Sets the integral time in 0.01 sec units for PI
control used to estimate polarity.
There is usually no need to change.
You set the damping factor of the speed
estimation for high frequency injection. N8-57
(high frequency superimposed selection) is valid
at the time of the 1. Unit is [-]
Sets the pull-in current during acceleration as a
percentage of the motor rated current (E5-03).
Set to a high value when more starting torque is
needed.
Set n8-48 [Pull-in/Light Load Id Current] to the
level of the load current (q-axis current) to be
applied.
Set n8-78 [Medium Load Id Current] to the level
of the load current (q-axis current) to be applied.
Set n8-49 [Heavy Load Id Current] to the level of
the load current (q-axis current) to be applied.
Sets the level of the pull-in current for midrange
loads.
Sets the U monitor that shows in Drive Mode.
This parameter is only enabled for LED keypads.
Selects the display units for the frequency
reference and output frequency.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min
3: User-selected units
Sets the contrast of the digital operator LCD. A
setting of "0" is the lightest contrast and a setting
of "10" is the darkest contrast.
5: Normal contrast
Drive U1 Monitor Select 1
Drive U1 Monitor Select 2
Selects the type of Auto-Tuning to be used.
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: StaTun for LinetoLine Resistance
Sets the motor rated power in kilowatts (kW).
Note: If motor power is given in horsepower,
power in kW can be calculated using the
following formula: kW = HP x 0.746
YASKAWA America, Inc. PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
Setting Range
Initial Setting
GA500
V1000
GA500
-10.00~
1.0~100.0
3.0
10.00
0.1~5.0
0.00~9.99
1.0
A1-02
0~200
0~200
Depend
0~255
0.0~250.0
30.0
0~255
0.0~250.0
50.0
0~255
0.0~250.0
90.0
-200.0~
0~255
0.0
200.0
104~855
104~813
106
A1-02
0~3
0~3
Depend
0~10
0~5
5
0~3,
0~21
0
6~13
0~3,
0~21
0
6~13
0,
0~2
0
2~3
0.00~
0.03~
0.40
650.00
650.00
Base Unit
V1000
DEC Hz
1.00
DEC
0.01
DEC
%
50
DEC
%
30.0
DEC
%
50.0
DEC
%
90.0
DEC
%
0.0
DEC
106
DEC
0
DEC
3
DEC
0
DEC
0
DEC
0
DEC kW
0.40