7 Transfer of Parameter Settings
Reg.
Param.
Name
No.
No.
Terminal MP Pulse
0x0431 H6-06
Train Monitor
Selection
Motor Overload
0x0480 L1-01
Protection Selection
Momentary Power
0x0485 L2-01
Loss Operation
Selection
KEB Deceleration
0x048A L2-06
Time
Momentary Power
0x048B L2-07
Loss Ridethru Time
0x048E L2-10
KEB Detection Time
Stall Prevention
0x048F L3-01
Selection during
Acceleration
Stall Prevention
0x0493 L3-05
Selection during Run
Stall Prevention Level
0x0494 L3-06
during Run
Acceleration
0x0466 L3-21
Deceleration Rate
Calculation Gain
0x046F L3-25
Load Inertia Ratio
Pre-Stall Acceleration
0x0456 L3-27
Time
36
Description
Selects a function for the pulse train monitor
output terminal MP. Inputs the "x-xx" portion of
the Ux-xx parameter to be monitored.
Enables or disables the motor overload
protection using electronic thermal protectors.
0: Disabled
1: Variable Torque
2: Constant Torque 10:1 Speed Range
3: Constant Torque 100:1 Speed Range
4: PM Variable Torque
5: PM Constant Torque
6: Variable Torque (50Hz)
Selects the drive operation performed when a
momentary power loss occurs.
0: Disabled
1: Enbl with Timer
2: Enbl whl CPU act
3: KEB Mode
4: KEB Stop Mode
5: KEB Decel to Stp
Sets the time required to decelerate to zero speed
when a KEB command is input from a multi-
function input terminal.
Set the time (in seconds) to accelerate to the set
speed after recovery from a momentary power
loss. If setting = 0.0, then active acceleration
time is used instead.
Sets the minimum duration to operate the KEB
after a momentary power loss is detected.
Selects the method of the Stall Prevention During
Acceleration function.
0: Disabled
1: General Purpose
2: Automatic Decel Reduction
3: ILim Mode
Enables or disables the Stall Prevention During
Run function.
0: Disabled
1: Decel Time 1
2: Decel Time 2
3: Intelligent
This parameter is enabled when L3-05 is set to
"1" or "2". Drive rated current is set as 100%.
Decrease the set value if stalling or excessive
current occurs with the default settings.
Sets the proportional gain used to calculate
acceleration and deceleration rates.
Sets the ratio between the connected machinery
and the motor.
Pre-Stall Acceleration Time
YASKAWA America, Inc. PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
Setting Range
Initial Setting
GA500
V1000
GA500
0,31,101,
0,
102,105,
31,
116,501,50
101,102,
2,702,801~
105,
102
809,821~
116,
825,831~
501,502,
839,851~
801~809
855
0~4,
A1-02
0~6
Depend
6
0~5
0~2
0
0.0~6000.0 0.0~200.0
0.0
0.0~6000.0 0.0~25.5
0.0
0~25500
0~2000
50
0~3
0~2
1
A1-02
0~3
0~2
Depend
C6-01,
5~150
30~150
L8-38
Depend
0.00~
A1-02
0.10~10.00
200.00
Depend
0.1~1000.0 0.0~1000.0 1.0
0~5000
20~150
60
Base Unit
V1000
DEC
102
A1-02
DEC
Depend
DEC
0
DEC sec
0.0
DEC sec
0.0
DEC ms
50
DEC
1
DEC
1
C6-01,
DEC
%
L8-38
Depend
A1-02
DEC
Depend
DEC
1.0
DEC ms
60