Reg.
Param.
Name
No.
No.
Speed Agreement
0x0499 L4-01
Detection Level
Speed Agreement
0x049A L4-02
Detection Width
Speed Agreement
0x049B L4-03
Detection Level(+/-)
Speed Agreement
0x049C L4-04
Detection Width (+/-)
0x04AE L8-02
Overheat Alarm Level
Heatsink Cooling Fan
0x04B6 L8-10
Operation Selection
Current Unbalance
0x04E1 L8-31
Detection Current
Level
Side-by-Side
0x04EC L8-35
Selection
Low Carrier
0x04F1 L8-40
Frequency Time
STPo I Detection
0x0471 L8-51
Level
High Slip Braking
0x0589 N3-02
Current Limit
Line-to-Line Motor
0x0570 N6-01
Resistance Online
Tuning
Superimposed
0x0563 N8-36
Harmonic Frequency
YASKAWA America, Inc. PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
Description
Sets the speed agree detection level or the motor
speed detection level.
Sets the speed agree detection width or motor
speed detection width.
Sets the speed agree detection leveler the motor
speed detection level.
Sets the speed agree detection width or motor
speed detection width.
When the heatsink temperature exceeds the value
set in this parameter, an Overheat Alarm (OH)
will occur. Requires that one of the multi-
function digital output terminals (H2-xx) be set
to 20.
Controls the heatsink cooling fan operation.
0: Fan On-Run Mode - Fan will operate only
when the drive is running and for L8-11 seconds
after RUN is removed.
1: Fan always on - Cooling fan operates
whenever the drive is powered up
2: Fan ON in heating of Drive - Fan runs when
drive main circuit overheat is detected
Sets the current level to activate Current
Unbalance Protection Detection function with
the drive rated current at 100%.
0: Disabled (standard installation).
1: Side-by-Side installation.
2:NEMA 1 Type 1 enclosure
3: Finless / Fin outside
Sets the amount of time the drive will operate
with a reduced carrier frequency.
The carrier frequency derating function during
run is disabled when this parameter is set to
0.00 s.
Sets the STPo [De-synchronization Error] on the
basis of the output current.
Sets the maximum current to be drawn during an
HSB stop. Higher n3-02 settings will shorten
motor stopping times but cause increased motor
current, and therefore increased motor heating.
Tunes the line-to-line motor resistance online.
0: Disabled
1: Enabled (Line-to-line resistance tuning)
2: Enabled (Voltage Adjustm)
In with PG vector control (A1-02 = 3), it is not
possible to enable the resistance online
adjustment only. There is a need to set C3-28=2.
Sets the frequency in Hz for the superimposed
signal used for superimposed harmonics.
7 Transfer of Parameter Settings
Setting Range
Initial Setting
GA500
V1000
GA500
A1-02
0.0~590.0
0.0~400.0
Depend
(all 0.0)
A1-02
0.0~20.0
0.0~20.0
Depend
A1-02
-590.0~
-400.0~
Depend
590.0
400.0
(all 0.0)
A1-02
0.0~20.0
0.0~20.0
Depend
kVA
50~150
50~130
Depend
0~2
0~1
0
1~100
0.0~100.0
3
0~3
0~3
0
A1-02
0.00~2.00
0.00~2.00
Depend
0.0~300.0
0.0~150.0
0.0
C6-01,
0~200
100~200
L8-38
Depend
0~2
0~1
0
200~5000
200~1000
500
Base Unit
V1000
DEC Hz
0.0
DEC Hz
2.0
DEC Hz
0.0
DEC Hz
2.0
kVA
DEC °C
Depend
DEC
0
DEC
30.0
kVA,
DEC
O2-09
Depend
DEC sec
0.50
DEC
%
0.0
DEC
%
150
DEC
1
DEC Hz
500
37