Motor Leakage
0x0313 E2-06
Inductance
0x031A E3-04
(FMAX)
Motor 2 Base
0x031C E3-06
Frequency (FA)
Motor 2 Minimum
0x031D E3-07
Output Frequency
(FB)
Motor 2 Minimum
0x031F E3-09
Output Frequency
(FMIN)
Motor 2 Mid Output
0x0345 E3-11
Frequency 2
0x0324 E4-04
Motor 2 Motor Poles
Motor 2 Leakage
0x0326 E4-06
Inductance
Motor Poles (for PM
0x032C E5-04
motor)
Operation Selection at
0x0381
F1-02
PG Open Circuit
(PGO)
Trace Sampling from
0x03A5 F6-04
Communications
Option Board
Terminals MA, MB,
0x040B H2-01
and MC Function
Selection (relays)
Terminals P1 Function
0x040C H2-02
Selection (open-
collector)
Terminals P2 Function
0x040D H2-03
Selection (open-
collector)
Drive Transmit Wait
0x042A H5-06
Time
0x0435 H5-09 CE Detection Time
YASKAWA America, Inc. PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
Description
Sets the voltage drop due to motor leakage
inductance as a percentage of motor rated
voltage. This value is automatically set during
Auto-Tuning.
Sets the maximum output frequency used for
motor 2.
Sets the base frequency used for motor 2.
Sets the middle output frequency used for
motor 2.
Sets the minimum output frequency used for
motor 2.
Used only for fine-tuning the V/f ratio within the
rated output range. This setting rarely needs to be
changed.
Sets the number of poles of motor 2. This value
is automatically set during Auto-Tuning.
Sets the voltage drop due to motor leakage
inductance as a percentage of rated voltage of
motor 2. This value is automatically set during
Auto-Tuning.
Sets the number of motor poles.
Selects the motor operation when PGo [PG
Disconnect] is detected.
0: Ramp to stop
1: Coast to stop
2: Fast Stop (use C1-09)
3: Alarm only
4: No alarm display
Sets the delay time until bUS [Option
Communication Error] issues are detected.
Terminals MA, MB, and MC Function Selection
(relays)
Terminals P1 Function Selection (open-collector)
Terminals P2 Function Selection (open-collector)
Set the delay time from when the drive receives
data to when the drive sends data.
Sets the time required to detect a
communications error. Adjustment may be need
when networking several drives.
7 Transfer of Parameter Settings
Setting Range
Initial Setting
GA500
V1000
GA500
kVA
0.0~60.0
0.0~40.0
Depend
A1-02,
40.0~590.0 40.0~400.0
O2-09,kVA
Depend
A1-02,
0.0~590.0
0.0~400.0
O2-09,kVA
Depend
A1-02,
0.0~590.0
0.0~400.0
O2-09,kVA
Depend
A1-02,
0.0~590.0
0.0~400.0
O2-09,kVA
Depend
A1-02,
0.0~590.0
0.0~400.0
O2-09,kVA
Depend
2~120
2~48
4
kVA
0.0~60.0
0.0~40.0
Depend
E5-01
2~120
2~48
Depend
0~4
0~3
1
0.0~12.0
0.0~5.0
2.0
0x0~
0x0~0x192 0x00E
0x1A7
0x0~
0x0~0x192 0x000
0x1A7
0x0~
0x0~0x192 0x002
0x1A7
0~65
5~65
5
0.0~25.0
0.0~10.0
2.0
Base Unit
V1000
kVA
DEC
%
Depend
A1-02,
O1-
DEC
O2-09,kVA
04
Depend
A1-02,
O1-
DEC
O2-09,kVA
04
Depend
A1-02,
O1-
DEC
O2-09,kVA
04
Depend
A1-02,
O1-
DEC
O2-09,kVA
04
Depend
A1-02,
O1-
DEC
O2-09,kVA
04
Depend
DEC
4
kVA
DEC
%
Depend
E5-01
DEC
Depend
DEC
1
DEC sec
2.0
HEX
0x00E
HEX
0x000
HEX
0x002
DEC ms
5
DEC sec
2.0