10 Retrofitting
10.5  Checking and updating the flap control
easyTouch appliances
1.
2.
Standard appliances
1.
2.
Operating and installation instructions
Check whether the flap control has been activated.
When opening the appliance door, the air-intake flap
must open.
When closing the appliance door, the air-intake flap
must close.
If necessary, activate the flap control in Service mode
under 'IDM' with 'C12/C13' as follows:
C12 at 300 --> activate
C13 at 930 --> air-intake flap opens when the appli‐
ance door is open.
Check whether the flap control has been activated. To
do so, briefly start a cooking profile.
When opening the appliance door, the air-intake flap
must open.
When closing the appliance door, the air-intake flap
must close.
If necessary, activate the flap control in the 'C12/C13'
service programs as follows:
C12 at 300 --> activate
C13 at 930 --> air-intake flap opens when the appli‐
ance door is open.