Important Safety Instructions - Zip HydroTap G4 Installation Instructions Manual

Filtered and chilled drinking water for commercial kitchens
Table of Contents

Advertisement

This manual contains important safety and installation instructions for the Zip HydroTap
Please read all warnings, installation requirements and installation instructions before installing any Zip
HydroTap
G4. This system must be installed in accordance with water supply byelaws,
®
current IEE regulations and relevant local authority byelaws.
Safety
This appliance is not intended for use by children under 8 or persons (including children
under 8) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning the use of the appliance by
a person responsible for their safety. Children should be supervised to ensure that they do not play with the
appliance. Cleaning and user maintenance shall not be made by children without supervision.
Refrigerant
The Zip HydroTap
G4 Command-Centre
®
refrigeration unit must be carried out by an accredited service provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all
installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power
outlet must be in a safe visible position for connection.
Lifting
Take care when lifting the Zip HydroTap
you feel this is beyond your personal capabilities, please seek assistance with the lift. The weight of the
Command-Centre
is marked on the packaging. Do not lift the Command-Centre
TM
of its connections. Refer to the technical specification, see page 8, for the weight of the product.
Airflow
The Zip HydroTap
G4 operates within the ambient temperature range 5ºC - 35ºC. Proper air circulation
®
must be provided. The system will operate satisfactorily only if the recommended air gaps are provided. See
Section 1 Ventilation, page 10, for correct installation to prevent overheating.
Frost protection
If the HydroTap
G4 is located where the ambient air temperature could fall below 5ºC when the heater is
®
not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the
connecting pipework and fittings.
Positioning
It is important to ensure the Command-Centre
The Command-Centre
TM
up. The tap must be located above the Command-Centre
pages 12.
Page 6 of 16

Important safety instructions

contains R134A refrigerant under pressure. Maintenance of the
TM
G4. The Command-Centre
®
o
TM
must have it's base mounted in a horizontal position with all inlets and outlets facing
801525UK G4 Commercial chilled only installation instructions - June 2016 - V2.04
may exceed safe lifting limits. If
TM
is positioned in an accessible area close to the floor level.
. See Section 2, Command-Centre
TM
G4.
®
by the front cover or any
TM
installation,
TM