Page 1
Installation instructions Zip HydroTap G4 ® Filtered and chilled drinking water for commercial kitchens. VENTILATION IS ESSENTIAL Affix model number label here 801525UK READ SECTION 2 'VENTILATION' READ BEFORE YOU START 801525UK G4 Commercial chilled only installation instructions - June 2016 - V2.04...
Page 2
Tap options The G4 series offers a range of interchangeable taps to suit the customer's needs Classic HydroTap G4 range ® These standalone taps are directly compatible with the G4 Command-Centre Arc / Cube range Elite range Page 2 of 16 801525UK G4 Commercial chilled only installation instructions - June 2016 - V2.04...
Index HydroTap G4 specifications ® Installation check list ........................4 General product features ......................5 Important safety instructions ......................6 Warnings and regulatory information ................... 7 Major components and accessories ..................... 8 Technical specifications ....................... 8 Before installation and site requirements ..................9 Installation instructions Step 1 - Measure and cut all the tap holes, fit the taps : Refer to 803341UK Tap installation...
Installation checklist Before installation • Read the instructions and check if there is adequate space to install all of the components. • Note Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. • Check the mains water pressure is within min. / max. requirements (see page 9). • Note This product must be fitted to a potable water supply.
General product features Thank you for purchasing a Zip HydroTap G4. Please read and follow these instructions carefully to ensure ® safe and trouble free operation. If help and advice is required, please call 0345 6 005 005. What is the Zip HydroTap G4 ? ®...
Important safety instructions This manual contains important safety and installation instructions for the Zip HydroTap ® Please read all warnings, installation requirements and installation instructions before installing any Zip HydroTap G4. This system must be installed in accordance with water supply byelaws, ®...
• All installation and service work must be completed by trained and suitably qualified tradespeople. Faulty operation due to unqualified persons working on this product, or any other Zip product may void warranty coverage. • As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local regulations and relevant standards.
For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be CLAMP AV160/125G4 required. (One GPO is for the Zip HydroTap and the other for the Booster heater). NOTE: feed each of the three tubes and NOTE: Check the cable lengths and outlet positions before proceeding.
See Technical specification, page 8 for dimensions. See sections 2, page 12 for installation instructions. • For Zip HydroTap G Chilled models, 1 x 220-240V AC, 13A socket will be ® required.
Section 1 Ventilation When installing air flow vents, the following tools will be required • Jigsaw and drill. • Keyhole or wall board saw. 1.1 Preferred ventilation arrangement shown below. The ducted vent kit supplied with the Command-Centre exhausting through the kick-space should be used, to provide adequate ventilation in all conditions.
Page 11
Ventilation 1.2 Alternative arrangements (Dual fan kit) In situations where the preferred arrangement cannot be used or will not work effectively e.g. • Single cupboard where the 100mm grille spacing cannot be achieved. • Where there are openings in the back of the cupboard allowing exhaust air to recirculate into the cupboard space.
Section 2 Command-Centre installation 2.1 HydroTap G4 Chilled models ® Refer to 803341UK Tap installation instructions (for Arc / Cube also refer to the tube kit assembly instructions) supplied with the tap. Elite Classic Arc / Cube Braided hose fitting Install the mains water braided hoses to the Command-Centre before locating in place.
User manual. 3.1 Select the language Language selection screen Initial commissioning screen Zip Chilled Zip Chilled 3.2 Filter flush Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation.
Internal fault Call Zip Service Call an electrician, a plumber, or Zip on 0345 6 005 005 for assistance, service, spare parts or enquiries. Page 14 of 16 801525UK G4 Commercial chilled only installation instructions - June 2016 - V2.04...
Furthermore this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the...
The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more of the following patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, US5099825 and SA2006/08043. Other patents are in force and patent applications are pending.
Need help?
Do you have a question about the HydroTap G4 and is the answer not in the manual?
Questions and answers