DL-10 – RS-485 Remote Temperature and Humidity

2.2 Specification

Temperature Sensor
Measuring Range
Resolution
Accuracy
Precision
Humidity Sensor
Measuring Range
Resolution
Accuracy
Precision
Communication
Interface
Baudrate
Data Format
Protocol
Max. Modules on same bus
Power
Input Range
Power Consumption
Mechanical
Dimensions (W x L x H)
Installation
Environment
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Copyright © 2019 ICP DAS CO., Ltd. All Rights Reserved.
-20 ~ +60°C (-4 ~ +140 °F)
0.1°C
Typical: ± 0.4°C; refer to Figure 2
± 0.1% RH
10 ~ 95 % RH
0.1 % RH
Typical: ± 3% RH @ 20 ~ 80 % RH; refer to Figure 1
± 0.1% RH
RS-485; non-isolated
1200 ~ 115200 bps
N, 8, 1
Modbus RTU
+10 ~ +30 V
0.05 W
25 mm x 20.2 mm x 30 mm
DIN-Rail; Wall Mount
-20 ~ +60°C
-30 ~ +80°C
10 ~ 95 % RH, Non-condensing
32