E 2013 Nordson Corporation
RetroFit Refill System with Nordson Level Sensor
Basic (Empty Level) Calibration
CAUTION! Do not attempt empty calibration with a full melter. Doing so will
result in an overfill condition.
1. Allow tank to reach application temperature.
2. Adhesive level should be at or below the bottom of the probe.
3. Close lid.
4. Press SW3 (blue button) until all LEDs stop changing color
(approximately 5 seconds).
Precision (Full Level) Calibration
1. Allow tank to reach application temperature.
2. Hand fill the adhesive level so that the pellets are at the top of the probe.
3. Close lid.
4. Within 30 seconds, press SW2 (white button) until all LEDs stop
changing color (approximately 5 seconds).