Retrofit for Mesat Melters
Install the Control Box
Figure 10
Part 1121938_02
(contd)
Secure the ground wire
9. Secure the ground wire to the melter tank.
10. Attach the right side panel with the five screws previously removed.
11. See Figure 11. Thread a customer supplied, 14-18 AWG power cord into
the control box.
12. Connect the power wiring to the terminal blocks in the control box.