Maintenance
Model: AUH2436ZGDA
Note: Recover all refrigerant and isolate power before removing the electronic expansion valve.
Step
1. Remove the electric box.
2. Remove the fixed block.
3. Remove the electronic
expansion valve.
58

Electronic Expansion Valve Removal

Picture
CONNECT SERIES SERVICE MANUAL
Work instruction
Remove the upper, lower and front
panels.
Loosen the wire clamp at the bottom
of the electric box
Unscrew the screws of electric box.
The connection wires inside and
outside the electric box should be
removed.
When removing the electric box, be
careful to protect the components.
Remove the fixed block between the
electronic expansion valve and the
pipe.
Take off the coil of electronic
expansion valve.
Loosen the connection pipe of
electronic expansion valve by brazing.
Then remove the connection pipe.
Note: When brazing the pipe, do
not let the flame bunt the other
components.