Haier GE APPLIANCES Connect Series Service Manual page 58

Split heat pumps
Table of Contents

Advertisement

Maintenance
Note: Make sure all refrigerant has been recovered and power is isolated before removing the outdoor coil.
Step
2. Remove the electric box.
3. Remove motor support.
4. Remove the outdoor coil.
5. Remove the outdoor coil
56
Outdoor Coil Removal
Picture
CONNECT SERIES SERVICE MANUAL
Work instruction
Loosen the wire clamp at the
bottom of the electric box.
Unscrew the screws of electric box.
The connection wires inside and
outside the electric box should be
removed.
When removing the motor
support, be careful to protect the
components.
Heat the brazed joint with a torch
until the pipes separate.
Note: When brazing the pipes, do
not let the flame burn the other
components. The brazing points
of the outdoor coil are steel and
copper brazed points. Be sure to
maintain the brazing quality.
Loosen the securing screws of coil
support. Take off the plate type
heat exchanger and the support as
a whole.