Maintenance
Note: Be sure the refrigerant is recovered and power is isolated before removing the compressor.
Step
3. Break off the pipes that
connect to the compressor.
4. Remove the compressor
from the chassis
5. Fix the new compressor
back onto the chassis.
64
Compressor Disassembly
Picture
CONNECT SERIES SERVICE MANUAL
Work instruction
Braze the pipes that are connected to
the compressor.
Then remove the pipes.
Note: When brazing the pipes, do
not let the flame burn the other
components
Take out the compressor and replace it.
Note: When replacing the compressor,
avoid touching the nearby pipeline and
components.
After replacing the compressor,
tighten up the screws at the foot of
compressor.