Heat Pump Water Heater Installation and Service Manual Model HP200M2 HP250M2 HP250CM2 Please read this manual carefully prior to your use of this water heater. The appearance of the water heater given in this manual is for reference only.
1. Product safety statement 1. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
2. Functionings & principles A low-pressure liquid refrigerant is vaporized in the heat pump's evaporator and passed into the compressor. As the pressure of the refrigerant increases, so does its temperature. The heated refrigerant runs through a condenser coil within the storage tank, transferring heat to the water stored there.
600*629*1692mm 600*629*1987 mm 600*629*1987 mm Packing dimension without pallet 736*695*1810 mm 736*695*2120 mm 736*695*2120 mm Packing dimension with pallet 736*695*1940 mm 736*695*2250 mm 736*695*2250 mm Net/Gross weight 104/118kg 117/131kg 136/150kg * The COP and noise level data was tested in Haier lab...
4. Description of parts and components Heat pump structure(HP200M2/HP250M2) Outlet of condensation water Hot water Safety outlet valve Inlet for cold water/drain outlet Air outlet Air inlet...
Page 7
Heat pump structure(HP250CM2) Outlet of condensation water Safety Hot water valve outlet Circulating entrance Sensor pocket Inlet for cold Circulating water/drain exit outlet Air outlet Air inlet HP250CM2...
Page 8
Exploded view Description Electric heater Electric cover Front cover - down Display panel Front cover - up Control box Top cover Air grille Air channel - up Four-way valve Compressor Air channel - down Tank case Handle Solar or boiler sensor (HP250CM2 only) (From heat pump) Boiler signal wire...
Page 9
2. Ev vaporator Evap porator effect ts: it makes th he liquid refri igerant absor rbs heat and is s evaporated into steam. 3. C ondenser A co ondenser: hig gh-temperatu ure high-press sure refrigera ant vapor is condensed in nto liquid, du uring cond...
Page 10
6. H High Voltage S Switchgear High h-voltage swi itch is to pre event excessiv ve pressure i in the system m, thus affecti ing the life o of the syste em componen nts, high-pres ssure of the h high-voltage s switch is 2.8M MPa.
9. R Refrigerant Heat t pump refrig gerant is R134 4a, ODP valu ue is 0, no da amage to the ozone layer. R134a refrig gerant cans s appearance is as follows: 5. I Installat tion intro oduction a. I nstallation n precauti - Do...
Page 12
10 to 35°C. Keep an adequate distance between the working heat-pump and the resting places. b. Installation dimensions (mm) HP200M2/HP250M2 HP250CM2...
Page 13
Air outlet Air inlet Pipe 160mm Display Pipe connection...
Page 14
- Remove vent grid first. - Install diameter 160mm duct. - Pressure drops from duct must be lower than or equal to the static pressure of the fan. - If the pressure drops out of range, the performance of the appliance will be impaired. Maximum length of the air connection 5m (Diameter of air connection 160 mm).
Page 15
Habitable room or outside air (with two ducts): -Can obtain free heat from the garage. -If the outside air temperature is low, connection to the outside air may lead to overconsumption of electricity. -Referring installer menu, adjust the fan speed Installation caution When making the connections, you should respect the standards and local directives.
Page 16
- If the mains pressure exceeds 80% of safety valve, a pressure reducer must be installed upstream of the appliance. Do not connect the domestic hot water connection directly to copper pipes in order to prevent galvanic couples in iron/copper (risk of corrosion). It is compulsory to fit the domestic hot water connection with a dielectricconnection (not supplied).
Page 17
Connection to solar collectors (Version HP250CM2) Installation of sensor(heat pump): 1/2"nipple(not supplied) sensor pocket 3/4" to 1/2" (not supplied) reducing bush (not supplied) T-piece sensor (not supplied) Installation of sensor(solar controller): heat pump sensor pocket(φ6mm) sensor pocket plug clamp screw sensor(not supplied) 230V 50Hz...
Page 18
f. Connection to gas boiler (Version HP250CM2) Installation of sensor(heat pump): 1/2"nipple(not supplied) sensor pocket 3/4" to 1/2" (not supplied) reducing bush (not supplied) T-piece sensor (not supplied) Installation of sensor(boiler controller): heat pump sensor pocket(φ6mm) sensor pocket plug clamp screw sensor(not supplied) Thermostatic...
Page 19
Installation of Solar or boiler Installation of Solar or boiler sensor (From Solar controller sensor(From heat pump): Boiler controller): 1/2"nipple (not supplied) sensor pocket(φ6mm) sensor pocket plug Circulating sensor pocket clamp entrance (not supplied) screw solar or boiler sensor- 3/4" to 1/2" solar or boiler T-piece from...
Page 20
- The phase line, zero line and ground line inside a power socket used in your home shall be wired correctly without any wrong positioning or false connection, and internal short circuit shall be avoided. Wrong wiring may cause fire accidents. Off-peak power signal wire connection(HP200M2/HP250M2) 123kwh Auto Off-peak power signal wire...
Page 21
- Connect the boiler back-up connector (boiler back-up).refer to the boiler instruction manual. - Referring installer menu, adjust the parameters NOTE: 1, Off-peak power switching signal cable: to receive the ‘low price electric signal’ , 5 volts if you measure the tension Between the brown and the blue line voltage of (Machine OFF) 2, Boiler signal cable: to give authorization signal to boiler , if you measure the tension Between the brown and the blue line voltage of 0 volts.
6. Operation and functions Display Functions: Electrical leakage protection The control system of this machine features an electricity leakage protection function. 10-minutes protection When starting the machine immediately after electricity input, the fan and the compressor will start at the same time. When starting the machine immediately after shutdown, the system goes into the protection mode and starts after 10 minutes, which is considered to be normal.
Page 23
Description of the pictograms Symbol Description Power ON/OFF switch Working mode selection Confirm button Timer adjust Boost mode. Heat pump and electric heater are activated at the same time. Auto mode - Prior using heat pump; - If heat pump works more than the default 8 hours , start the electric heater - The default working time can be adjust in the installer settings.
Installer settings - To open the installer settings, press switch off the system, then press at the same time for 10 seconds. - When menu is open, press to change the value of the settings. - Press to confirm the settings. - Press to close the menu.
Page 25
7. Checking and maintenance - Installation and maintenance of the appliance must be done by a qualified professional . - Before working on the appliance, Shut down the machine and cut off the power supply . - Do not touch with wet hands. - Maintenance operations are important to guarantee optimum performance and extend the life of the equipment.
8. Faults and protection Digital Whether to start Action Fault type electric heater indication Automatically start Operating temperature protection electric heater Air exhaust temperature protection Evaporation high temperature Compressor protection protection Three times or more, Evaporation low temperature you need to manually protection start BOOST Compressor over-current...
Page 27
Fault code identification method• • Operating conditions:When leakage current ≥15mA, the system cut off the power supply, display "E1". Leakage current ≤7.5mA, not action. Operating conditions:The actual water temperature ≥85 ℃;...
Page 31
mperature sen nsor resistan nce measurem ment method mperature sens sor resistance e measuremen nt method (m method of me asuring the r esistance valu ue of the c compressor o of the same, b but is switched d to the small l resistance o f the interfac e unit).
Page 32
Check the compressor line is through the current transformer Check the signal cable is short-circuited Press the yellow button to switch to the picture, when a short circuit, there is a beep,...
the resistance is zero. Check the tank heater for leaks Press the yellow button to switch to the picture shown, turn the heating power measurements, if leakage resistance is zero, if not leak, show resistance. Check that the power cord L, N lines are in the same order into the leakage protection coil 9.
Page 34
Use a s screwdriver to remov ve the two screws 2、 Remove the Cover Use a a screwdriver r to remov ve the screws 3、 Remove the Air channel l and fan 2. remo ove the 1. remove Air channel l - up 3.
Page 35
② A After remove e the magnesi ium rod, acco ording to the consumption n of magnesiu um rod, deter rmine ther you need d to replace. magnesiu um rod cover magnesium r 5、 Remove the temperature e sensor ① Remove e the fixing sc crews, remov ve the water ta...
Page 36
ontroller pan Ambient tem mperature se ensor(yello ow) Exhaust tem mperature se ensor(white e) Evaporator s sensor 1(re ed) Evaporator s sensor 2(g grey) Tank temp perature sen sor(red) Sola r or boiler sens Leakag ge protectio n coil nicipal low power Display pane swit...
Page 37
7、 Remove Ele ctric heater ①Remove F Front cover - down After the Cover i is removed, use a screw wdriver to remov e the bottom m two screws s of the Fro nt cover – down. ②Remove E Electrical cov Use a scre ewdriver to r remove the 2...