Error Codes - Haier GE APPLIANCES Connect Series Service Manual

Split heat pumps
Table of Contents

Advertisement

Troubleshooting

Error Codes

No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Error code
E1
Compressor high pressure protection
E3
Compressor low pressure protection
E4
Compressor air discharge high-temperature protection
F2
Condenser temperature sensor error
F3
Outdoor ambient temperature sensor error
F4
Discharge temperature sensor error
F6
ODU tube temperature sensor error
EE
ODU memory chip error
H4
Overload
H5
IPM protection
H6
DC fan error
H7
Driver out-of-step protection
HC
PFC protection
Lc
Startup failure
P0
Driver reset protection
P5
Over-current protection
P6
Master control and driver communication error
P7
Driver module sensor error
P8
Driver module high temperature protection
PA
AC current protection
Pc
Driver current error
PL
Bus low-voltage protection
PH
Bus high-voltage protection
PU
Charge loop error
ee
Drive memory chip error
e1
High pressure sensor error
C4
ODU jumper cap error
CONNECT SERIES SERVICE MANUAL
Error
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents