Troubleshooting

Failures Not Caused by Errors

If your heat pump fails to function normally, please first check the following items before contacting service:
Problem
The heat pump
doesn't run
Bad cooling or
heating effect.
The following situations are not operation failures:
Problem
Mist comes from the
heat pump.
The heat pump
generates excessive
noise.
Dust comes from the
heat pump.
The heat pump
generates some
smell.
• Check the above items and adopt the corresponding corrective measures. If the
NOTICE:
36
Cause
The compressor is protected by a 3
minute time-delay.
Wire connection is wrong.
Fuse or circuit breaker is broken
Power failure.
Power plug is loose.
Thermostat has weak battery.
Air inlet and outlet of the units have
been blocked.
Improper temperature setting
Fan speed is too low.
Air flow direction is not right.
Doors or windows are open.
Exposed under direct sunshine.
Too many heat sources in the room.
Filter is blocked or dirty.
Air inlets or outlets of the units are
blocked.
Time of occurrence
During operation.
System switches to heating mode
after defrosting.
The heat pump is buzzing at the
beginning of operation.
When the unit is turned on, it purrs.
About 20s after the unit first
enables the heating mode or there
is refrigerant brushing sound when
defrosting under heating.
There is hissing sound when the
unit is started or stopped and a
slight hissing sound during and after
operation.
There is a sound of crunching during
and after operation.
There is a hissing sound when the
unit is turned on or suddenly stopped
during operation or after defrosting.
The unit starts operation after being
unused for a long time.
During operation.
heat pump continues to function poorly, please stop the heat pump immediately and
contact a local service contractor.
CONNECT SERIES SERVICE MANUAL
Corrective measure
Please wait for time delay protection.
Connect wires according to the wiring diagram.
Replace the fuse or switch on the circuit breaker.
Restart after power is resumed.
Re-insert the power plug.
Replace the batteries.
Clear the obstacles and keep the room for the units
well ventilated.
Select a proper temperature.
Select a proper fan speed.
Change the direction of air louvers.
Close them.
Draw curtains or louvers in front of the windows.
Remove unnecessary heat sources.
Send for a professional to clean the filter.
Clear away obstacles that are blocking the air inlets
and outlets of the units.
Cause
If the unit is running under high humidity conditions, the
air in the room will condense.
Defrosting process will generate some water, which will
turn to water vapor.
Thermostat will be buzzing when it starts working. The
noise will become weak 1 min later.
When the system is just started, the refrigerant is not
stable. About 30s later, the purr of the unit will dissipate.
It's the sound of 4-way valve switching direction. The
sound will disappear after the valve changes its direction.
It's the sound of gaseous refrigerant that stops flowing
and the sound of drainage system.
Because of temperature change, front panel and other
components may be expanding and contracting.
Because refrigerant suddenly stops flowing or changes
the flow direction.
Dust inside the units come out together with the air.
The room smell or the smell of cigarette comes out
through the units