Haier GE APPLIANCES Connect Series Service Manual page 53

Split heat pumps
Table of Contents

Advertisement

Maintenance
Model: AUH2436ZGDA
Note: Make sure all refrigerant is recovered and power is isolated before removing compressor and gas liquid separator.
Step
1. Remove wires.
2. Break off the pipes that
connecting to the compressor/
gas liquid separator.
3. Loosen the compressor's
base connectors / gas liquid
separator's base nuts.
4. Remove the compressor/
gas liquid separator from the
chassis.
Compressor/Gas Liquid Separator Removal
Picture
CONNECT SERIES SERVICE MANUAL
Work instruction
Loosen the securing screws of the
wires with a screwdriver.
Remove the wires.
Note: When removing the
wires, mark the wire terminals
corresponding to their color so as to
avoid misconnection.
Braze the pipes that are connected
to the compressor/gas liquid
separator.
Then remove the pipes. Note: When
welding the pipes, do not let the
flame burn the other components.
Use a wrench to twist off the
compressor/gas liquid separator's
base nuts.
Take away the compressor/gas liquid
separator and replace with a new
one.
Note: When replacing the
compressor/gas liquid separator,
avoid touching the nearby pipeline
and components.