IMPORTANT!
Internal box
Follow these steps to avoid difficulties in door panel adjustment and cosmetic cap fitment.
●
Door panel
B
Ensure to protect the finish of the Stainless steel door panels.
●
attachment kit
For non-water dispensing door panels: Leave the protective film on the panels when hanging and remove the film only when installation is complete.
●
Remove hanging brackets
Side bracket
(10)
Remove the M8 washers and M8 nuts from the
1
M8 studs at the top the door (A). Keep the
washers and nuts to reuse later.
Remove the hanging bracket from the top of
2
each door and set aside (B) for later installation.
Side strap
(10)
Door handle kit
M5x25 pan head socket
screw (12x)
Door panel set
M5x14 mush cross-head
(SS) screw (34)
Tools
Hex key
FPA spanner
Powered driver
DOOR PANEL INSTALLATION - STAINLESS STEEL
A
B
Attach the door and drawer handles (C)
Remove the plastic plugs from the handle holes
3
(4 per each door panel).
Align the handle holes with the door panel
4
holes and secure with M5x25 pan head socket
screws (4 per each door panel).
Note: Door handle kit available and must be
purchased separately. Refer to 'Components'
for more details.
Attach the hanging brackets (D)
Align the bracket to the holes and secure
5
with M5x14 mush cross-head SS screws (14).
Attach side brackets and straps (E)
Align the brackets and straps to the holes on
6
the side of the panel and secure with M5x14
mush cross-head SS screws (20).
E
C
C
D
D