6.7
FC Warm
• Check setting of control.
• Check door seal.
• Check frost pattern of FC evaporator. If fully frosted, check defrost by forcing a
defrost.
• If defrost doesn't work, check defrost sensor and/or defrost heater and fuses.
• If defrost is working, checking temperature of the FC evaporator and cooling plate
is recommended to rule out or confirm system or compressor fault/s.
6.8
Alarm Sounds When Door Is Opened
• Count how many beeps, check fault code table for probable cause.
6.9
Light Not Functioning
• Check light globe and ensure light is fully screwed in.
• Check connections.
• Is light switch depressing correctly? Check position of plunger and/or is the dairy
cover in place.
14