Chapter 6 – Communication
6-4
Register addresses 4GGPP are shown in Table 6-1 below. In this table GG is
the group number, and PP is the parameter number within the group.
4GGPP
40001 – 40006
00 Data sets
40101 – 40126
01 Actual Values
41001 – 41003
10 Group 10
...
...
49801 – 49805
98 Group 98
49901 – 49909
99 Start-up Data
Table 6-1 Parameter Mapping.
The register addresses between the groups are invalid. No reads or writes are
allowed for these addresses. If there is an attempt to read or write outside the
parameter addresses, the Modbus Plus interface will return an exception code
back to the controller.
GG
01 Data set 1
02 Data set 2
...
06 Data set 6
01 Process Speed
...
26 Control Dev.
01 Param 10.1
...
03 Param 10.3
...
01 Param 98.1
...
05 Param 98.5
01 Language
...
09 Motor ID Run
Installation and Start-up Guide for NMBP-01