The Agitation Valve is designed to allow
air to escape from the pump so it can
easily prime. When you're running in the
field, a little liquid runs through the
Agitation valve back to the tank. (You
will need to adjust the amount of
agitation.)
The Agitation Valve can also be used
to evenly mix additives by running the
pump with the electronic control valves
closed.
The John-Blue Ground Drive pump comes in either single or
double piston configuration. It does not require any control
valves. The rate is controlled by an adjustment on the pump
and it naturally compensates for different speeds since it is
driven off of the main frame wheel.
Agitation Valve (Hydraulic Pump Units Only)
Optional Ground Drive Pump