IX. Q & A

9.1 Power

o Unable to turn off the power by pressing
Press the switch and hold it for about 1 second and release the
button when the monitor is turned off.
o Unable to splice as number of times as the splicer normally does with the
battery that has been fully charged.
If the power saving mode is not activated, the battery runs out
quickly. Please refer to [Setting Menu] for more information. If the
battery has not been used for a while, charge it again until it is
charged fully.
Use a new battery if the current battery was used for a long period of
times and its suggested lifetime is passed. Since the battery works
based on chemical reactions, power generated decreases at a low
temperature and, in particular, it runs out very quickly when the
temperature is below zero. Also, the battery runs out fast when it is
used at a high temperature because the power consumption
increases. If you cannot charge the battery fully, do as instructed
below.
o LED is not turned on while charging the battery.
Disconnect the AC power cord from the charger and connect the DC
cord to the charging jack. Connect the AC power cord in 10 to 15
seconds. The LED of the battery is turned on red and charging begins.
o Nothing is displayed on the indicator of the battery.
.