Specifications; General Specifications - UCL SWIFT KR12A User Manual

Optical fiber arc fusion splicer
Hide thumbs Also See for KR12A:
Table of Contents

Advertisement

II. Specifications

2.1 General specifications

Subject
Fiber alignment
Applicable fibers
Fiber count
Applicable fiber
dimensions
Fiber cleave length
Splicing modes
Average splice Loss
Return loss
Splicing time
Splice loss estimate
Sleeve heating time
Applicable protection
sleeve
Storage of splice
result
Tension test
Ribbon
SM(G.652), MM(G.651), DS(G.653), NZDS(G.655),
SM(G.657)
Single fiber, 2~12 Ribbon fiber
Single: Cladding diameter 125μm, Coating diameter
250μm, 900μm
Ribbon: Cladding diameter 125μm, Ribbon fiber
thickness 0.25 to 0.40mm
10mm
Splicing: 300, Heat: 100, Strip: 50
SM: 0.05dB, MM: 0.02dB, DS: 0.08dB, NZDS: 0.08dB
> 60dB
Typical 20 sec with standard SM (ITU-T G.652)
Available
1~2 core 20 sec
4~12 core 50 sec
40mm, 60mm (Fiber)
The last 10,000 results to be stored in the internal
memory. (Image 10,000 results)
2N / 4.4N (Option)
Description