UCL SWIFT KR12A User Manual page 64

Optical fiber arc fusion splicer
Hide thumbs Also See for KR12A:
Table of Contents

Advertisement

The arc can be adjusted by two steps. The
Arc1 Power
first step is [arc1] and second is [arc2].
[arc1] is set here.
Arc1 Time
It sets the time of [arc1].
It is the second step of arc. [arc2] is set
Arc2 Power
here.
It sets the time of [arc2].
In general, [arc2 time] is set to "OFF". It is
possible to set a very long arc time;
Arc2 Time
however, if the [arc1 time] and [arc2 time]
is longer than 30 seconds, the electrode
can be damaged.
It sets arc to ON and OFF alternatively
while the [arc2] is performing arc
discharge. The duration of [arc2] operating
Arc2 On-Time
time is set here. Arc discharge time ON
has to be set always in order to conduct
re-arc.
It is used to set the duration of [arc2] non-
operating time. When the [arc2] stops
Arc2 Off-Time
working, the re-arc stops as well. Set this
parameter to "OFF" if a continuous re-arc
is required.
It sets the re-arc time.
It automatically sets the re-arc to
discharge the same amount as [Arc 2] in
Re-arc Time
[Splice Mode Edit]. If arc 2 is set to ON and
OFF, the re-arc is automatically set to ON
and OFF as well.
The splice loss rate increases sometimes
when the fiber becomes thinner. The taper
Taper Splice
splice is set to "OFF". The attraction is
decided by following three parameters.
It sets the time between the last moment
Taper Wait
of fiber's moving forward and the initiation
of attraction.
Non
Editable
Editable
62

Advertisement

Table of Contents
loading