UCL SWIFT KR12A User Manual page 23

Optical fiber arc fusion splicer
Hide thumbs Also See for KR12A:
Table of Contents

Advertisement

Cleaner Ass'y
Be careful not to wet the equipment.
Maintain the unit in a clean condition at all times because many of splicing
problems are caused by dust or moisture.
Keep and use the unit at room temperature as it could be deformed by heat.
Keep the equipment from being shaken or physically impacted as it could be
broken.
Never use organic solvents such as acetone except alcohol to clean rubber part
of the equipment.
i. When cleaning, press down on the alcohol dispenser 2 or 3 times, using
cleaning cotton (wipe) as shown in the picture below.
At this time, to avoid splashing the alcohol please cover the top part of
dispenser with cleaning cotton and push it.
ii. If no alcohol is discharged, open cap and refill the dispenser.
Add alcohol after completely removing it from the Swift KR12A body by
pulling upward. It is connected to the body by magnet.
iii. The recommended cleaning fluid is MCC-POC03M.