Introduction
1
1
Figure 1.3 is a block diagram of the internal components of
the frequency converter. See the table for Figure 1.3 for
their functions.
Area
1
Mains input
2
Rectifier
3
DC bus
4
DC reactors
5
Capacitor bank
6
Inverter
7
Output to motor
8
Title
Functions
3-phase AC mains supply to the
frequency converter.
The rectifier bridge converts the
AC input to DC current to supply
inverter power.
Intermediate DC bus circuit
handles the DC current.
Filter the intermediate DC circuit
voltage.
Prove mains transient protection.
Reduce RMS current.
Raise the power factor reflected
back to the line.
Reduce harmonics on the AC
input.
Stores the DC power.
Provides ride-through protection
for short power losses.
Converts the DC into a controlled
PWM AC waveform for a
controlled variable output to the
motor.
Regulated 3-phase output power
to the motor.
Danfoss A/S © 01/2015 All rights reserved.
®
VLT
AQUA Drive FC 202
Area
8
Figure 1.3 Frequency Converter Block Diagram
1.4.4 Enclosure Types and Power Ratings
For enclosure types and power ratings of the frequency
converters, refer to chapter 8.9 Power Ratings, Weight, and
Dimensions.

1.5 Approvals and Certifications

More approvals and certifications are available. Contact the
local Danfoss partner. Frequency converters of enclosure
type T7 (525–690 V) are UL certified for only 525–600 V.
The frequency converter complies with UL508C thermal
memory retention requirements. For more information,
refer to the section Motor Thermal Protection in the product
specific design guide.

1.6 Disposal

Title
Functions
Input power, internal processing,
output, and motor current are
monitored to provide efficient
operation and control.
User interface and external
Control circuitry
commands are monitored and
performed.
Status output and control can be
provided.
Do not dispose of equipment containing
electrical components together with
domestic waste.
Collect it separately in accordance with
local and currently valid legislation.