Specifications
8.8.1 CE Compliance
200–240 V, Enclosure sizes A, B, and C
Enclosure
A2
A3
A4
A5
B1
B2
8
8
B3
B4
C1
C2
C3
C4
Table 8.19 200–240 V, Enclosure Sizes A, B, and C
74
Power [kW]
Recommended
fuse size
0.25–2.2
gG-10 (0.25–1.5)
gG-16 (2.2)
3.0–3.7
gG-16 (3)
gG-20 (3.7)
0.25–2.2
gG-10 (0.25–1.5)
gG-16 (2.2)
0.25–3.7
gG-10 (0.25–1.5)
gG-16 (2.2–3)
gG-20 (3.7)
5.5–11
gG-25 (5.5)
gG-32 (7.5)
15
gG-50
5.5–11
gG-25
15–18
gG-32 (7.5)
gG-50 (11)
gG-63 (15)
18.5–30
gG-63 (15)
gG-80 (18.5)
gG-100 (22)
37–45
aR-160 (30)
aR-200 (37)
22–30
gG-80 (18.5)
aR-125 (22)
37–45
aR-160 (30)
aR-200 (37)
Danfoss A/S © 01/2015 All rights reserved.
®
VLT
AQUA Drive FC 202
Recommended
maximum fuse
gG-25
gG-32
gG-32
gG-32
gG-80
gG-100
gG-63
gG-125
gG-160 (15–18.5)
aR-160 (22)
aR-200 (30)
aR-250 (37)
gG-150 (18.5)
aR-160 (22)
aR-200 (30)
aR-250 (37)
Recommended circuit
Maximum trip level
breaker
Moeller
PKZM0-25
PKZM0-25
PKZM0-25
PKZM0-25
PKZM4-63
NZMB1-A100
PKZM4-50
NZMB1-A100
NZMB2-A200
NZMB2-A250
NZMB2-A200
NZMB2-A250
[A]
25
25
25
25
63
100
50
100
160
250
150
250
MG20MC22

Advertisement

Table of Contents
loading

Table of Contents