Change Between The Energy Conservation Modes - insys icom GSM small 2.0 Manual

Table of Contents

Advertisement

Functions
11.12.2

Change Between the Energy Conservation Modes

The following is a short overview of the possible changes from and into the differ-
ent energy conservation modes. The possibilities in sleep mode depend on the set-
ting of the sleep mode with AT+CFUN.
Next
mode
Current
mode
Normal
Sleep
Power-Down
Power-Down RTC-
Alarm
Table 10: Energy conservation modes - change between the modes
56
Normal
Sleep
AT+CFUN
- - -
Reset via reset
terminal
RTS falling
edge
Unsolicited
result code
- - -
Incoming call
AT command
Incoming SMS
RTC alarm
AT+CFUN=1
Reset via reset
- - -
terminal
Reset via reset
- - -
terminal
Power-Down RTC-
Power-Down
Alarm
AT^SMSO
- - -
AT^SMSO
- - -
- - -
RTC alarm
AT^SMSO
- - -
INSYS GSM small 2.0