Pepperl+Fuchs VB14N Manual page 70

Host mode programming
Hide thumbs Also See for VB14N:
Table of Contents

Advertisement

HOST MODE PROGRAMMING
PARAMETER
Deactivation Event
Alternative
Deactivation Event
Deactivation
Timeout (ms)
Activate On Any
Diagnostics Error
Deactivate When
All Diagnostic Errors
Recovered
Event Counter
Event Counter
Mode
Quality Counter
Threshold
BUILT-IN DIGITAL OUTPUT LINES / OUTPUT 2
Use
Line State
Activation Event
68
COMPLETE PATH
/IO
/Out/Out0
/Deactive
/IO
/Out/Out0
/Deactive1
/IO
/Out/Out0
/Timeout
/IO
/Out/Out0
/ActiveDiagnoErr
/IO
/Out/Out0
/DeactiveDiagnoNoErr
/IO
/Out/Out0
/EventCounter
/IO
/Out/Out0
/EventCounterMode
/IO
/Out/Out0
/QualityCounter
Threshold
/IO
/Out/Out1
/Use_1
/IO
/Out/Out1
/Idle
/IO
/Out/Out1
/Active
SHC
PT
VALUE
21
1
0 = None
7 = Timeout
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
516
1
0 = None
5 = Phase On
6 = Phase Off
8 = Quality Counter >=
Threshold
22
0
Range: 40 to 15000
551
1
0 = Disable
1 = Enable
552
1
0 = Disable
1 = Enable
553
0
Range: 1 to 70000
554
1
0 = Consecutive
1 = Not Consecutive
5273 0
Range: 1 to 100
5317 1
1 = Local
2 = External Fieldbus
23
1
0 = Normally Open
1 = Normally Closed
24
0 = None
1 = Complete Read
2 = Partial Read